Analysis of the Role of DCIM in Energy Optimization for Data Centers in Indonesia

Authors

  • Muhammad Fuady Telkom University
  • Teguh Kurniawan Telkom University
  • Basuki Rahmad Telkom University

DOI:

https://doi.org/10.62123/enigma.v4i1.233

Keywords:

Data center infrastructure management, Digital twin, Energy efficiency, Green data center, Power usage effectiveness

Abstract

The global digital transformation, accelerated by the COVID-19 pandemic and the massive adoption of generative artificial intelligence (AI) architectures, has triggered an exponential surge in the construction of hyperscale data center infrastructure, positioning data centers among the most energy-intensive industrial facilities in the world. This research presents a comprehensive analysis of the role of Data Center Infrastructure Management (DCIM) as an instrument to diagnose, orchestrate, and improve energy efficiency, quantified specifically through the reduction of the Power Usage Effectiveness (PUE) metric. Using a framework of systematic review and empirical multi-case analysis, this research explores the operational thermodynamic dynamics that cause inefficiencies, such as zombie servers and over- provisioning of HVAC systems. Quantitative analysis demonstrates that DCIM intelligence features can help reduce PUE, with several institutional facilities successfully lowering baseline PUE from 1.83 to 1.51 while cutting cooling loads by up to 48%. In Indonesia, DCIM integration supports the fulfillment of the mandates of SNI 8799:2020 and SPBE guidelines and helps mitigate peak load resilience risks for PT PLN (Persero).

Downloads

Download data is not yet available.

References

[1] V. Rozite, E. Bertoli, and B. Reidenbach, “Data centres and data transmission networks,” International Energy Agency, Paris, France, 2024. [Online]. Available: https://www.iea.org/energy-system/buildings/data-centres-and-data-transmission-networks

[2] E. Masanet, A. Shehabi, N. Lei, S. Smith, and J. Koomey, “Recalibrating global data center energy-use estimates,” Science, vol. 367, no. 6481, pp. 984–986, 2020, doi: 10.1126/science.aba3758.

[3] Kementerian Energi dan Sumber Daya Mineral, Handbook of Energy and Economic Statistics of Indonesia 2023. Jakarta, Indonesia: Pusdatin ESDM, 2023. [Online]. Available: https://www.esdm.go.id/assets/media/content/content-handbook-of-energy-and-economic-statistics-of-indonesia-2023.pdf

[4] PT PLN (Persero), Statistik PLN 2024 – Data Operasional (Unaudited). Jakarta, Indonesia: PT PLN (Persero), 2025. [Online]. Available: https://web.pln.co.id

[5] Badan Standardisasi Nasional, SNI 8799:2020: Spesifikasi teknis dan sistem manajemen pusat data. Jakarta, Indonesia: BSN, 2020.

[6] G. A. Brady, N. Kapur, J. L. Summers, and H. M. Thompson, “A case study and critical assessment in calculating power usage effectiveness for a data centre,” Energy Convers. Manag., vol. 76, pp. 155–161, 2013, doi: 10.1016/j.enconman.2013.07.035.

[7] KPMG Indonesia, “Beyond capacity: Building Indonesia’s intelligent & sustainable data centers,” KPMG Siddharta Widjaja & Rekan, Jakarta, Indonesia, Mar. 2026. [Online]. Available: https://kpmg.com/id/en/insights/2026/03/beyond-capacity-2026.html

[8] The Green Grid, “Green Grid metrics: Describing datacenter power efficiency,” The Green Grid, Technical Committee White Paper, 2007.

[9] B. Whitehead, D. Andrews, A. Shah, and G. Maidment, “Assessing the environmental impact of data centres part 1: Background, energy use and metrics,” Build. Environ., vol. 82, pp. 151–159, 2014, doi: 10.1016/j.buildenv.2014.08.021.

[10] R. Telyatnykov, T. Burmeister, and P. K. Iffert, “Data center requirements under the new German Energy Efficiency Act,” White & Case LLP, Oct. 25, 2023. [Online]. Available: https://www.whitecase.com/insight-alert/data-center-requirements-under-new-german-energy-efficiency-act

[11] D. Huang, “Data center infrastructure management,” in Data Center Handbook: Plan, Design, Build, and Operations of a Smart Data Center, 2nd ed., H. Geng, Ed. Hoboken, NJ, USA: Wiley, 2021, pp. 627–644, doi: 10.1002/9781119597537.ch33.

[12] B. Garrard, “Data center sustainability: Even better than renewable is energy not used,” CoreSite, n.d. [Online]. Available: https://www.coresite.com/blog/data-center-sustainability-even-better-than-renewable-is-energy-not-used (accessed Oct. 29, 2026).

[13] M. Schmitt, “Lowering PUE: The impact of DCIM,” Nlyte Software, Feb. 20, 2020. [Online]. Available: https://www.nlyte.com/blog/dcim-lowers-pue/

[14] R. Mahdavi and W. Tschudi, “Wireless sensor network for improving the energy efficiency of data centers,” Lawrence Berkeley National Laboratory, Berkeley, CA, USA, Rep. LBNL-6253E, Mar. 2012. [Online]. Available: https://eta-publications.lbl.gov/sites/default/files/wireless_sensor_case_study.pdf

[15] A. Habibi Khalaj, T. Scherer, and S. K. Halgamuge, “Energy, environmental and economical saving potential of data centers with various economizers across Australia,” Appl. Energy, vol. 183, pp. 1528–1549, 2016, doi: 10.1016/j.apenergy.2016.09.053.

[16] A. Shehabi, S. J. Smith, E. Masanet, and J. Koomey, “Data center growth in the United States: Decoupling the demand for services from electricity use,” Environ. Res. Lett., vol. 13, no. 12, Art. no. 124030, 2018, doi: 10.1088/1748-9326/aaec9c.

[17] Ponemon Institute, “2016 cost of data center outages,” Ponemon Institute LLC, Traverse City, MI, USA, Jan. 2016.

[18] D. Donnellan et al., “Uptime Institute global data center survey results 2024,” Uptime Institute, New York, NY, USA, 2024. [Online]. Available: https://uptimeinstitute.com/resources/research-and-reports/uptime-institute-global-data-center-survey-results-2024

[19] TÜV NORD Indonesia, “SNI pusat data berdasarkan SNI 8799,” TÜV NORD Indonesia, Jakarta, Indonesia, n.d. [Online]. Available: https://www.tuv-nord.com/fileadmin/user_upload/PDB_-_SNI_Pusat_Data_8799_-final-ID_JUNI25_1_.pdf (accessed Oct. 29, 2026).

[20] Huawei Carrier, “Achieving sustainable data center growth,” Huawei Technologies, Shenzhen, China, 2022.

[21] M. Lubis, A. R. Lubis, and E. Ernovianti, “Disruptive innovation service oriented framework: A case study of transportation in Indonesia,” in Proc. 7th Int. Conf. Multidisciplinary Research (ICMR), vol. 1, 2018, pp. 496–504, doi: 10.5220/0008889604960504.

[22] M. Lubis, R. C. Annisyah, and L. Lyvia Winiyanti, “ITSM analysis using ITIL V3 in service operation in PT. Inovasi Tjaraka Buana,” IOP Conf. Ser.: Mater. Sci. Eng., vol. 847, Art. no. 012077, 2020, doi: 10.1088/1757-899X/847/1/012077.

[23] L. Syafiraliany, M. Lubis, and R. W. Witjaksono, “Analysis of critical success factors from ERP system implementation in pharmaceutical fields by information system success model,” n.d. [Online]. Available: https://www.semanticscholar.org/paper/2274ee382a49b51228aa513ed8098f50c02bb3a4

[24] E. Rosmaini, T. F. Kusumasari, M. Lubis, and A. R. Lubis, “Insights to develop privacy policy for organization in Indonesia,” J. Phys.: Conf. Ser., vol. 978, Art. no. 012042, 2018, doi: 10.1088/1742-6596/978/1/012042.

Downloads

Published

2026-10-31

How to Cite

Muhammad Fuady, Teguh Kurniawan, & Basuki Rahmad. (2026). Analysis of the Role of DCIM in Energy Optimization for Data Centers in Indonesia. Electronic Integrated Computer Algorithm Journal, 4(1), 41–45. https://doi.org/10.62123/enigma.v4i1.233

Similar Articles

<< < 1 2 3 4 

You may also start an advanced similarity search for this article.